Skip to main content
. 2019 Nov 4;9(61):35878–35886. doi: 10.1039/c9ra06859g

Performance of FBG sensors in terms of magnetic field detection.

Detection mechanism Ferrofluid/nanoparticle Detection range Sensitivity Ref.
Wavelength shift Fe3O4 0–25 mT 86 pm/25 mT (no linear behavior) 23
Intensity of reflected power EMG 605 0–14 mT 1470 nW mT−1 24
Wavelength shift EMG 705 0–32 mT 106 pm/35 mT (no linear behavior) 25
Wavelength shift Fe3O4 0–166 mT 7400 pm/166 mT (no linear behavior) 26
Cladding mode intensity Ferromagnetic particles 7–15 mT −0.78 dB mT−1 27
Wavelength shift Fe3O4 < 10 nm 0–0.06 mT 1009 pm mT−1 Current study