Skip to main content
. 2022 Apr 4;322(6):F639–F654. doi: 10.1152/ajprenal.00398.2021

Table 3.

Measurements of renin-angiotensin-aldosterone system elements as reported in publications that included direct, prospectively obtained comparison of infarction and polectomy rats subjected to 5/6 nephrectomy

Time Postsurgery Measurement Value
Reference
Infarction Polectomy
2 wk Plasma renin content, ng ANG I/mL/h 10.2 ± 8.9 (±SD) 2.5 ± 1.8 (±SD)* Ibrahim et al. (15)
Plasma aldosterone, pg/mL 672 ± 591 (±SD) 194 ± 107 (±SD)*
Total kidney renin content, µg ANG I/h/kidney 127 ± 115 (±SD) 26 ± 18 (±SD)*
Systolic blood pressure, mmHg 166 ± 31 (±SD) 120 ± 16 (±SD)
3 days Plasma renin content, ng ANG I/mL/h 59.9 ± 9.6 (±SE) 12.8 ± 1.5 (±SE)* Griffin et al. (14)
Systolic blood pressure, mmHg ∼160 ± 10 (±SE)† ∼130 ± 5 (±SE)†
3 wk Plasma renin content, ng ANG I/mL/h 18.6 ± 3.5 (±SE) 9.3 ± 1.3 (±SE)*
Systolic blood pressure, mmHg ∼170 ± 10 (±SE)† ∼120 ± 5 (±SE)†

Both studies were performed in Sprague–Dawley rats. SD, standard deviation; SE, standard error.

*

Significantly different than infarction rats from the corresponding time point; †proteinuria values for this table were estimated from a graphical figure in the referenced study.