Skip to main content
. 2018 Jan 3;8(2):1140–1147. doi: 10.1039/c7ra10112k

Solution resistance (Rs), charge transfer resistance (Rct), Warburg resistance (Rw) and exchange current estimated based on the EIS experiments performed with the LFP-based samples A, B, C and D electrodes based on samples A, B, C and D.

Samples R s (Ohm) R ct (Ohm) R w (Ohm) i o (mA)
Sample A 10 76 11.0 0.335
Sample B 9 68 55.3 0.374
Sample C 9 57 54.9 0.446
Sample D 10 77 63.5 0.331