Comparison of the manufactured electrode for HQ, CC, RC and NO2− detection with other electrodes.
| Electrode | HQ | CC | RS | NO2− | Optimum pH | Ref. | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| D.La (μM) | L.Rb (μM) | D.L (μM) | L.R (μM) | D.L (μM) | L.R (μM) | D.L (μM) | L.R (μM) | |||
| CDs/r-GO/GCE | 0.17 | 0.5–1000 | 0.28 | 1.0–950 | 1.0 | 5.0–600 | — | — | 7 | 37 |
| AuNPs/Fe3O4–APTES–GO/GCE | 1.1 | 3–137 | 0.8 | 2–145 | — | — | — | — | 7.4 | 38 |
| P-rGO modified electrode | 0.08 | 10–170 | 0.18 | 4–50 | 2.62 | 10–180 | — | — | 7 | 39 |
| MWCNT–SH@Au GR | 4.17 | 54.5–1250.5 | 1 | 11–126 | 7.8 | 43.5–778.5 | 23.5 | 86–7500 | 7 | 12 |
| Au/pAMTa–MWNTs/GCE | 0.3 | 7.2–391.2 | 0.24 | 3.6–183.6 | 0.6 | 8.4–398.4 | 10 | 30–419 | 7 | 21 |
| GPE/PQ–BNWs | 0.12 | 0.76–362.7 | 0.2 | 0.74–321.9 | 0.82 | 4.99–970.6 | 4.5 | 14.9–2392.6 | 8 | This work |
Detection limit.
Linear range.