Skip to main content
. 2018 Jan 3;8(3):1337–1345. doi: 10.1039/c7ra05954j

Classification results of RBFNN models developed on optimal wavelengths with 3000 and 1100 samples of each variety in the calibration set.

Samples of each variety in the calibration set Calibration Prediction
1 2 3 Accuracy 1 2 3 Accuracy
3000 1 2799 48 153 93.30% 1176 49 75 90.46%
2 44 2907 49 96.90% 40 1196 64 92.00%
3 166 65 2769 92.30% 83 37 1180 90.77%
Total 94.17% 91.08%
1100 1 1010 20 70 91.82% 1184 49 67 91.08%
2 19 1063 18 96.64% 46 1195 59 91.92%
3 66 10 1024 93.09% 87 43 1170 90.00%
Total 93.85% 91.00%