TGA data of the E-54 thermosets containing PCL-b-PDMS-b-PCL triblock copolymer.
PCL-b-PDMS-b-PCL (wt%) | T d5 (°C) | Residue at 800 °C (%) |
---|---|---|
0 | 379.9 | 15.7 |
10 | 355.4 | 16.1 |
20 | 308.3 | 16.3 |
30 | 295.9 | 15.6 |
PCL-b-PDMS-b-PCL (wt%) | T d5 (°C) | Residue at 800 °C (%) |
---|---|---|
0 | 379.9 | 15.7 |
10 | 355.4 | 16.1 |
20 | 308.3 | 16.3 |
30 | 295.9 | 15.6 |