Skip to main content
. 2018 Jan 30;8(9):5013–5019. doi: 10.1039/c7ra13628e

Pyrite and chalcopyrite sensors applied to drinking water and H2O2 in disinfector samples.

Sensors Samples Number Measured by proposed H2O2 biosensor Measured by KMnO4-titrated method
Detected (μM) Added (μM) Found (μM) RSDa (%) Recovery (%)
Pyrite Drinking water 1 Not found 50 51.9 3.5 103.8 Not found
2 Not found 100 98.0 2.6 98.0 Not found
3 Not found 200 202.1 2.5 101.1 Not found
Disinfector samples 1 100.2 50 151.9 2.1 101.1 99.9
2 200.5 100 302.3 2.7 100.6 200.2
3 299.3 200 494.5 1.9 99.0 299.5
Chalcopyrite Drinking water 1 Not found 50 53.5 4.8 107.0 Not found
2 Not found 100 97.4 3.7 97.4 Not found
3 Not found 200 203.9 4.0 102.0 Not found
Disinfector samples 1 99.6 50 153.1 3.8 102.3 99.3
2 200.1 100 305.0 3.5 101.6 199.8
3 300.5 200 492.0 4.2 98.3 300.1
a

RSD (%) calculated from three separate experiments.