Skip to main content
. 2022 Apr 2;50(6):728–739. doi: 10.1007/s10439-022-02953-w

Table 1.

Key parameter results across cohorts from a previous study (Mayer et al., 2021)18, Experiment 1 and Experiment 2.

HYGE (M ± SD) Head Sensor (M ± SD)
Coronal axis Resultant Coronal axis Sagittal axis Axial axis
Mayer et al. (2021) (N = 13)
Peak angular velocity (rad/s) 250.51 ± 3.46 130.22 ± 11.17 128.55 ± 11.36 55.21 ± 14.46 60.04 ± 10.25
FWHM (ms) 5.82 ± 0.13 11.02 ± 1.17 7.50 ± 0.77
Experiment 1: straps (N = 3)
Peak angular velocity (rad/s) 254.18 ± 3.23 137.92 ± 14.35 132.92 ± 9.69 93.58 ± 40.07 64.19 ± 8.49
FWHM (ms) 5.72 ± 0.11 12.89 ± 0.25 7.88 ± 1.38
Experiment 1: cables (N = 3)
Peak angular velocity (rad/s) 251.81 ± 2.07a 126.37 ± 8.01 122.47 ± 11.14 74.89 ± 21.02 74.82 ± 14.64
FWHM (ms) 5.67 ± 0.06a 11.37 ± 0.64 7.73 ± 0.30
Experiment 2 (N = 6)
Peak angular velocity (rad/s) 168.39 ± 5.19 116.22 ± 7.99 112.54 ± 6.19 85.84 ± 26.52 48.25 ± 6.54
FWHM (ms) 7.95 ± 0.32 13.25 ± 0.38 9.37 ± 2.02

M mean, SD standard deviation, ms milliseconds, rad/s, radians per second, FWHM full width at half maximum

aHYGE data for one animal derived using mean imputation