Adsorption kinetics parameters of the different models for Co(ii) adsorption on the CMC and PCMC beads.
Initial concentration (mg L−1) | Pseudo-first-order | Pseudo-second-order | Intraparticle diffusion | |||||||
---|---|---|---|---|---|---|---|---|---|---|
Q e (mg g−1) | K 1 (h−1) | R 2 | Q e (mg g−1) | K 2 (g mg−1 h−1) | R 2 | K 3 (mg g−1 h−0.5) | C | R 2 | ||
50 | CMC | 17.76 | 0.0483 | 0.9949 | 21.71 | 0.0039 | 0.9988 | 1.6951 | 3.141 | 0.8550 |
PCMC | 10.77 | 0.2594 | 0.9618 | 23.78 | 0.0529 | 0.9998 | 3.6973 | 9.870 | 0.8243 | |
100 | CMC | 28.18 | 0.0316 | 0.9723 | 32.72 | 0.0020 | 0.9935 | 2.4965 | 3.642 | 0.9519 |
PCMC | 34.92 | 0.3941 | 0.9894 | 45.96 | 0.0176 | 0.9992 | 8.3918 | 13.22 | 0.8770 | |
200 | CMC | 30.22 | 0.0251 | 0.9886 | 37.44 | 0.0017 | 0.9861 | 2.7746 | 4.657 | 0.9733 |
PCMC | 40.35 | 0.6716 | 0.9936 | 50.05 | 0.0168 | 0.9980 | 14.201 | 8.369 | 0.9110 |