Skip to main content
. 2018 May 16;8(32):17879–17887. doi: 10.1039/c8ra01846d

TGA data of RPUFs.

Samples T initial a (°C) Stage 1 Stage 2 Stage 3 Char residue at 700 °C (%)
T max b (°C) W 1 c (%) T max b (°C) W 2 c (%) T max b (°C) W 3 c (%)
RPUF-0 243 252 90.7 312 64.5 617 22.3 5.4
RPUF-1 179 251 80.1 308 61.6 618 25.8 10.3
RPUF-2 216 255 83.7 315 67.2 630 35.4 26.1
RPUF-3 207 251 88.2 329 60.9 659 34.6 29.0
RPUF-4 202 254 84.3 314 66.0 664 33.0 29.8
a

T initial is the initial degradation temperature (temperature at 5.0% weight loss).

b

T max is the maximum-rate degradation temperature.

c

W is the weight remaining percentage at the maximum-rate degradation temperature.