Skip to main content
. 2018 May 15;8(32):17685–17693. doi: 10.1039/c8ra01998c

Samples data with dyes 10, 1 and 9. The Raman shift and Raman intensity maxima for the target and control spectra are reported, with the respective standard deviations calculated on the 4 replicates, at different concentrations of dye. In the last column are reported the on/off ratios.

Dye no. Dye equivalents Peak position (cm−1) Av comp SERS intensity (counts) Av non-comp SERS intensity (counts) Ratio (comp : non-comp)
10 1000 1607 91 ± 4 44 ± 6 2.06
3000 139 ± 10 62 ± 7 2.25
5000 179 ± 13 80 ± 15 2.24
7000 245 ± 16 112 ± 13 2.18
1 1000 1316 199 ± 7 11 ± 12 1.79
3000 415 ± 16 244 ± 13 1.70
5000 538 ± 34 189 ± 31 1.86
7000 630 ± 63 290 ± 20 2.17
9 1000 1607 917 ± 82 409 ± 57 2.24
3000 1351 ± 101 660 ± 69 2.05
5000 1513 ± 103 741 ± 56 2.04
7000 1282 ± 134 596 ± 89 2.15