Skip to main content
. 2018 May 22;8(33):18682–18689. doi: 10.1039/c8ra03153c

Treated AMD values for major contaminants at the end of 15 d simulation compared with the average concentrations measured experimentally. Uncertainty is expressed as the 95% confidence interval.

Component Average measured experimental value [mM] Modelled value at 15 d simulation [mM]
Effluent values
Total sulfur 16.8 ± 1.6 16.7
Total sodium 21.3 ± 2.5 21.3
Total calcium 3.3 ± 0.4 3.3
Total magnesium 2.1 ± 0.2 2.0
Total iron 0.09 ± 0.03 0.02 (Fe2+ and Fe3+)
Total aluminium 0.001 ± 0.002 0.02
pH 7.2 ± 0.002 7.2
A2/A3 loop values
Total sulfate 19.2 ± 3.2 19.0
Total sulfide 8.4 ± 3.3 8.4
Total chloride 40.3 ± 2.2 41.4
pH ∼7.3 6.3