Cyclic voltammetry potential window results in volts (V) at 400 mV s−1 scan speed in 0.15 M H2SO4 and 1 M KOH at 200 μA threshold.
| Fe at% | 0.15 M H2SO4 | 1 M KOH | ||||
|---|---|---|---|---|---|---|
| E pa | E pc | Pot. window | E pa | E pc | Pot. window | |
| ta-C | 2.7 | −2.5 | 5.2 | 1.8 | −2.3 | 4.0 |
| 2 | 2.4 | −1.2 | 3.6 | 1.4 | −1.8 | 3.1 |
| 5 | 2.4 | −1.1 | 3.5 | 1.1 | −1.8 | 2.8 |
| 10 | 2.2 | −1.1 | 3.3 | 1.0 | −1.7 | 2.7 |