. 2018 Jul 30;8(47):26897–26905. doi: 10.1039/c8ra03488e

Quantitative parameters of the DLLME – GC-MS method for the determination of the selected PEs.

Compound Linearity range (μg mL−1) r 2 LODa (μg mL−1) LOQb (μg mL−1) RSDc % EFd Recoverye (%)
Intra-day Inter-day
DMP 0.0010–1.0 0.9998 5.0 × 10−6 2.0 × 10−5 1.36 2.75 510 91.8
DEP 0.0010–1.0 0.9998 6.0 × 10−6 2.2 × 10−5 1.77 2.39 513 92.3
DBP 0.0010–1.0 0.9996 3.0 × 10−6 1.3 × 10−5 3.66 3.46 476 85.6
BBP 0.0015–1.0 0.9985 7.0 × 10−5 2.0 × 10−4 3.01 4.12 487 87.6
DEHP 0.0010–1.0 0.9987 4.0 × 10−6 1.5 × 10−5 2.25 3.33 532 95.8
a

Limit of detection (S/N = 3).

b

Limit of quantification (S/N = 10).

c

Relative standard deviation for (n = 3) at concentration of 0.02 μg mL−1 of each PEs.

d

Enrichment factor.

e

For water sample spiked with 0.02 μg mL−1 PEs.