Skip to main content
. 2022 May 6;10(2):e001541. doi: 10.1136/fmch-2021-001541

Table 2.

TA treatment methods and details for included studies

Author Year n treated Age range treated* Treatment method Treatment time Treatment provider Treatment setting Follow-up visits
Banerjee et al9 2020 136 36.7±7.3 WISAP Medical Technology GmbH, 100°C, no anaesthetic, multiple overlapping applications as needed 40 s Auxiliary nurse midwives† Community clinics 12 months
Campbell et al23 2016 381 WISAP, 100°C–120°C, no local anaesthetic, multiple overlapping applications as needed 30 s Unspecified health worker Facility 3 months, 6 months and 12 months
Chigbu et al18 2020 511 47.1±12.6 Device not specified, 100°C, multiple overlapping applications as needed 45 s Not reported Facility 6 months
Duan et al28 2021 74 31.5±5.2 Liger device, 100°C, no anaesthetic, multiple overlapping applications as needed 45 s Gynaecologist Facility 4, 8 months
Eakin et al24 2018 5 Device not specified, 100°C, no anaesthetic, multiple overlapping applications as needed 60 s Physician Facility N/A
Fokom Domgue et al25 2020 161 WISAP Medical Technology GmbH, 100°C, multiple overlapping applications as needed 45 s Nurse Primary health clinic N/A
Joshi et al10 2013 124 Device not specified, 105°C, no local anaesthetic, multiple overlapping applications as needed 45 s Unspecified health worker Community clinics 6 months
Joshi et al26 2015 27 WISAP Medical Technology GmbH, 105°C, no local anaesthetic, multiple overlapping applications as needed 45 s Physician or Nurse† Community clinics N/A
Mungo et al19 2020 293 40.4±8.7 Liger device, 100°C, no local anaesthethic, number of applications not specified 20 s Clinical officer—equivalent to a physician assistant in the USA† Community clinics 4–6 weeks
Naud et al22 2016 52 31 (27–40) WISAP Medical Technology GmbH, 100°C, no local anaesthetic, multiple overlapping applications as needed 20 s Not reported Facility 12 months
Pinder et al11 2020 250 Liger device, 100°C, no anaesthetic, multiple overlapping applications as needed 40 s Nurse Primary health clinic 2 weeks and 6 months
Sandoval et al20 2019 319 Liger device, 100°C, analgesia (NSAIDs) offered post-treatment, multiple overlapping applications as needed 45 s Physicians† Facility 1 month
Viviano et al21 2017 110 WISAP Medical Technology GmbH, 100°C, no anaesthetic, multiple applications as needed 60 s Gynaecologist† Facility 1 month
Zhao et al12 2021 170 41.0 (35–47) WISAP Medical Technology GmbH or Liger device, 100°C–110°C, no anaesthetic, multiple applications as needed 45 s Physician Primary health clinic 1 month, 6 months, 12 months and 18 months
Zhao et al27 2020 96 WISAP Medical Technology GmbH or Liger device, 100°C, no anaesthetic, multiple applications as needed 45 s Unspecified health worker Primary health clinic 4 weeks

*Average ±SD or median (IQR).

†Based on personal communication with authors (Dr Partha Basu, 2021; Dr Smita Joshi, 2021; Dr Chemtai Mungo, 2021; Dr Silvia de Sanjose, 2021; and Dr Manuela Viviano, 2021).

NSAIDs, non-steroidal anti-inflamatory drugs; TA, thermal ablation.