Skip to main content
. 2022 May 9;12(22):13896–13916. doi: 10.1039/d2ra00966h

The calculated coefficients of the prediction models and P-values obtained from the ANOVA test results a.

Term RSDFX & DFP RSDFP & IS TFDFX TFDFP Run time
Coef. p-value Coef. p-value Coef. p-value Coef. p-value Coef. p-value
I 2.2582 0.0004* 2.5758 <0.0001* 1.3392 <0.0001* 1.4079 <0.0001* 7.0995 <0.0001*
X −0.6521 0.0035* −0.2156 0.0002* 0.0274 0.0793 0.0189 0.6373 −0.3714 0.0007*
Y −0.2845 0.0748 0.0383 0.1502 0.0873 0.0010* 0.0655 0.1456 −0.0510 0.3653
Z −1.1108 0.0003* −0.5558 <0.0001* −0.0110 0.4218 −0.0327 0.4289 −1.7230 <0.0001*
XY 0.00345 0.9815 −0.1088 0.0075* −0.0156 0.3195 −0.0073 0.8706 −0.1928 0.0197*
XZ 0.30036 0.0868 −0.3592 <0.0001* −0.0189 0.2373 0.0306 0.5025 0.3170 0.0026*
YZ 0.4524 0.0233* −0.1058 0.0082* 0.0084 0.5737 0.0388 0.3988 −0.1304 0.0696
XYZ −0.2328 0.1703 −0.3147 <0.0001* −0.0344 0.0628 −0.0555 0.2590 −0.0788 0.2371
X 2 0.21398 0.4686 0.1648 0.0194* −0.0385 0.2150 −0.0966 0.2912 −0.2631 0.0626
Y 2 −0.4120 0.1964 0.00303 0.9533 0.0279 0.3576 −0.0457 0.6054 0.2456 0.0792
Z 2 0.38952 0.2179 −0.1068 0.0823 −0.0405 0.2009 −0.0246 0.7786 0.6257 0.0025*
a

Highlighted values (bold) indicate significant effect on the corresponding response. Coef. = coefficient (slope), I = intercept, X = temperature, Y = pH, Z = % of organic solvent, Rs = resolution and TF = tailing factor.