Cone calorimeter data of pure EP and the EP/MPhP composites.
Sample code | TTIa (s) | PHRR (kW m−2) | THR (MJ m−2) | TSR (m2 m−2) |
---|---|---|---|---|
EP0 | 32 | 1111 ± 50 | 18.2 ± 0.3 | 3457 ± 300 |
EP/MPhP10 | 38 | 1008 ± 50 | 12.4 ± 0.3 | 2901 ± 300 |
EP/MPhP15 | 40 | 846 ± 50 | 12.2 ± 0.3 | 2640 ± 300 |
EP/MPhP20 | 41 | 545 ± 50 | 12.0 ± 0.3 | 2623 ± 300 |
TTI: Time to ignition; PHRR: peak of heat release rate; THR: total heat release; TSR: total smoke release.