Cone calorimeter data of pure EP and the EP/MPhP composites.

Sample code TTIa (s) PHRR (kW m−2) THR (MJ m−2) TSR (m2 m−2)
EP0 32 1111 ± 50 18.2 ± 0.3 3457 ± 300
EP/MPhP10 38 1008 ± 50 12.4 ± 0.3 2901 ± 300
EP/MPhP15 40 846 ± 50 12.2 ± 0.3 2640 ± 300
EP/MPhP20 41 545 ± 50 12.0 ± 0.3 2623 ± 300
a

TTI: Time to ignition; PHRR: peak of heat release rate; THR: total heat release; TSR: total smoke release.