Skip to main content
. 2018 Dec 18;8(73):42189–42199. doi: 10.1039/c8ra08531e

LOI, UL94 and MFI results of PLA and PLA composites.

Samples LOI (%) UL-94 ratinga MFI (g/10 min) Ignition of cotton
PLA 21.4 No rating 9 Yes
PLA5VP 25.8 V-0 24 No
PLA10VP 26.3 V-0 55 No
PLA10VA 19.5 No rating 22 Yes
a