Table 2. Percentages of mistakes per step, total percentages of patients making incorrect inhalation techniques per controller device.

Essential steps pMDI (n=44) pMDI with spacer (n=60)
Shake inhaler thoroughly 22.7 8.3
Remove the cap and keep inhaler in upright position 11.4 na
Remove cap and insert inhaler correctly into spacer na 1.7
Breathe out gently to residual volume 50.0 53.3
Close lips on inhaler or spacer mouthpiece 0.0 0.0
Press the canister at beginning of inhalation 40.9 na
Hold spacer level and press down firmly on canister once na 21.2
Inhale slowly and deeply 27.3 43.3
Hold breath for at least 10 seconds 27.3 48.3
Breath in and out through mouthpiece at least three times na 20.0
Patients performing incorrect inhalation techniques 33 (75.0%) 49 (81.7%)
Patients performing incorrect flow (<30 or >60 L/min) 28 (63.6%) 33 (55.0%)
Overall (incorrect technique and flow) 42 (95.5%) 54 (90.0%)

pMDI, pressurized metered-dose inhaler; na, not applicable to the device.