Table 2.
Index | This Work |
---|---|
Power of detector [mw] | 40 (1)/38 (2) |
Area [mm2] | 0.06 |
Detection accuracy [dBm] | −82 (1)/−81 (2) |
Detection time [μs] (3) | 1 (1) |
Maximum operating frequency [MHz] | 519 (1)/400 (2) |
(1) Simulation result. (2) Test result. (3) The time needed for one energy detection operation.