Skip to main content
. Author manuscript; available in PMC: 2022 May 16.
Published in final edited form as: ACS Chem Biol. 2021 Jun 30;16(7):1208–1214. doi: 10.1021/acschembio.1c00232

Table 2.

GDA Reaction Rates

HPLC
absorbance
emission
λ mntr a k 1 b t 1/2 c K M d k 2 d k2/KMd λ mntr a k 1 b t 1/2 c λ mntr a k 1 b t 1/2 c
G to X 260 26 ± 2 27 12 ± 9 36 ± 27 3.0 ± 0.3 270 22 ± 1 31
thGN to thXN 320 NR NR NR NR NR 355 NR NR 450e NR NR
tzGN to tzXN 260 32 ± 1 21 8 ± 3 32 ± 7 4.2 ± 1.0 355 25 ± 1 27 450f 24 ± 1 29
a

λmntr reported in nm and represents wavelength monitored.

b

Pseudo-first-order reaction kinetics slope of the exponential approximation in 10−3 s−1.

c

t1/2 is reaction half-life calculated assuming pseudo-first-order kinetics.

d

KM, k2, and k2/KM are reported in μM, s−1, and 106 M−1 s−1, respectively.

e

λexc at 360 nm for thGN reactions.

f