Skip to main content
. 2022 May 16;12(23):14665–14685. doi: 10.1039/d2ra01751b

The electrochemical variables premeditated through the Tafel polarization method for the corrosion protection of N80 steel in the 3.5% NaCl medium without and with changed doses of the synthesized hydrazides at 25 ± 1 °C.

Comp Conc, M Ecorr, mV i corr, μA cm−2 β a, mV dec−1 β c, mV dec−1 C.R. mmy−1 θ η%
Blank 0.00 915 113.0 ± 5.65 1512 152 51.46
H2HEH 1 × 10−6 906 33.1 ± 2.31 999 142 15.12 0.707 70.7
5 × 10−6 954 30.4 ± 3.04 1026 139 13.87 0.731 73.1
1 × 10−5 958 21.0 ± 1.95 1042 138 9.61 0.814 81.4
5 × 10−5 931 15.4 ± 1.50 844 142 7.04 0.864 86.4
1 × 10−4 902 8.8 ± 0.08 613 150 4.02 0.922 92.2
H2MEH 1 × 10−6 933 30.1 ± 2.65 1025 135 13.74 0.734 73.4
5 × 10−6 939 27.0 ± 2.70 883 133 12.32 0.761 76.1
1 × 10−5 962 18.4 ± 1.20 956 127 8.39 0.837 83.7
5 × 10−5 928 14.0 ± 0.96 757 144 6.41 0.876 87.6
1 × 10−4 911 7.6 ± 0.07 524 182 3.45 0.933 93.3