Skip to main content

Table 7.

Intrasession and intersession reliability of COP measure in dual-task paradigm associated with manipulated visual and somatosensory inputs in operated limbs

Test conditions Variables Intrasession Intersession
test retest
ICC ICC ICC SEM MMDC CV
Single task Eyes open Without Vibration ML 0.66 0.73 0.67 (0.24, 0.88) 0.13 0.37 12.89
AP 0.76 0.68 0.62 (0.16, 0.86) 0.28 0.78 18
mV 0.80 0.84 0.67 (0.24, 0.88) 0.17 0.48 15.93
Area 0.51 0.50 0.63 (0.17, 0.86) 0.68 1.89 37.17
With Vibration ML 0.71 0.70 0.43 (-0.10, 0.77) 0.25 0.69 12.84
AP 0.67 0.72 0.41 (-0.13, 0.76) 0.47 1.29 15.06
mV 0.91 0.81 0.76 (0.41, 0.92) 0.19 0.52 20.60
Area 0.69 0.72 0.45 (-0.09, 0.78) 1.39 3.86 36.46
Eyes closed Without Vibration ML 0.83 0.88 0.95 (0.85, 0.98) 0.07 0.20 30
AP 0.71 0.70 0.35 (-0.20, 0.73) 0.99 2.75 18.26
mV 0.87 0.87 0.79 (0.46, 0.93) 0.41 1.14 25.82
Area 0.53 0.53 0.56 (0.07, 0.84) 1.57 4.34 28.52
With Vibration ML 0.70 0.77 0.70 (0.29, 0.89) 0.29 0.81 17.24
AP 0.66 0.71 0.40 (-0.14, 0.76) 1.12 3.10 20.34
mV 0.80 0.93 0.68 (0.26, 0.89) 0.60 1.65 22.57
Area 0.53 0.53 0.52 (0.01, 0.82) 2.07 5.73 27.43
Dual task Eyes open Without Vibration ML 0.70 0.69 0.67 (0.24, 0.88) 0.15 0.42 14.94
AP 0.73 0.69 0.40 (-0.14, 0.76) 0.43 1.20 16.66
mV 0.73 0.70 0.61 (0.15, 0.86) 0.18 0.51 14.18
Area 0.62 0.60 0.58 (0.09, 0.84) 0.66 1.84 40.30
With Vibration ML 0.77 0.72 0.53 (0.02, 0.82) 0.19 0.53 11.76
AP 0.68 0.63 0.60 (0.12, 0.85) 0.38 1.05 18.15
mV 0.83 0.75 0.78 (0.44, 0.92) 0.13 0.36 15.69
Area 0.56 0.51 0.34 (-0.21, 0.73) 1.05 2.90 30.43
Eyes closed Without Vibration ML 0.73 0.75 0.73 (0.34, 0.90) 0.18 0.51 13.92
AP 0.76 0.73 0.71 (0.31, 0.90) 0.42 1.16 21.22
mV 0.82 0.92 0.72 (0.33, 0.90) 0.45 1.23 21.29
Area 0.53 0.56 0.50 (-0.02, 0.81) 1.96 5.43 33.36
With Vibration ML 0.69 0.69 0.50 (-0.02, 0.81) 0.30 0.84 10.22
AP 0.70 0.73 0.36 (-0.19, 0.74) 1.04 2.89 18.78
mV 0.79 0.80 0.60 (0.13, 0.85) 0.56 1.55 15.92
Area 0.57 0.54 0.21 (-0.34, 0.65) 2.51 6.95 21.31

ICC: Intraclass correlation coefficient, SEM: standard error of measurement, MMDC: minimal metrically detectable change, CV: coefficient of variation, ML: range of medial-lateral, AP: range of anterior-posterior, mV: mean velocity.