Skip to main content
. 2021 Sep 7;10:e00227. doi: 10.1016/j.ohx.2021.e00227

Table 4.

Resolution of the flow sensor for a variety of configurations, all values in L·min-1 unless otherwise indicated. with the differential pressure sensor configured in linear mode, and with a 10-bit ADC. The inter tenth-centile resolutions are shown.

Pressure sensor
125 Pa 500 Pa
Venturi 15–10 mm Bot 10% (23.6) .17 Bot 10% (46.8) 0.33
Top 10% (71.4) 0.055 Top 10% (142) 0.11
15–12 mm Bot 10% (39.6) 0.28 Bot 10% (78.6) 0.56
Top 10% (120) 0.093 Top 10% (238) 0.18