Skip to main content
. 2022 May 22;5(3):e646. doi: 10.1002/hsr2.646

Table 3.

Spirometry and oximetry values between sawmill workers and control.

Variables Sawmill workers (mean ± SD) Control (mean ± SD) Value
FVC (L) 2.32 ± 0.47 3.10 ± 0.44 <0.001
FVC (%) 65.34 ± 10.23 76.95 ± 12.21 <0.001
FEV1 (L) 2.35 ± 0.69 3.03 ± 0.35 <0.001
FEV1 (%) 72.21 ± 13.75 85.76 ± 9.88 <0.001
PEF (L/s) 6.54 ± 2.05 8.62 ± 1.37 <0.001
PEF (%) 82.80 ± 20.19 104.18 ± 17.03 <0.001
FEV1/FVC (%) 92.67 ± 4.62 96.36 ± 3.45 <0.001
FEF25 (L/s) 5.73 ± 2.03 7.21 ± 1.16 <0.001
FEF75 (L/s) 2.05 ± 0.61 2.80 ± 0.57 <0.001
FEF2575 (L/s) 3.52 ± 1.05 4.54 ± 0.94 <0.001
Heart rate (bpm) 84.88 ± 14.91 76.47 ± 9.72 <0.001
Oxygen saturation (%) 97.94 ± 2.37 98.34 ± 1.02 0.124

Note: t Test was performed on spirometry and oximetry parameters. Values are represented as mean ± standard deviation.

Abbreviations: FVC, forced vital capacity; FEV1, forced expiratory volume in 1 s; FEV1%, the ratio of FEV1/FVC; PEF, peak expiratory flow; FEF25, 25% flow of the FVC; FEF75, 75% flow of the FVC; FEF2575, average flow between 25% and 75% of the FVC.