Skip to main content
. 2022 May 23;12:8649. doi: 10.1038/s41598-022-12743-y

Table 4.

Lung segmentation results on the Haut dataset (mean ± standard deviation).

Accuracy (%) Specificity (%) Sensitivity (%) Dice coefficient (%) Jaccard Index (%)
Method 1 96.72 ± 1.47 98.23 ± 0.80 93.00 ± 5.50 94.92 ± 1.63 87.42 ± 2.95
Method 2 97.23 ± 0.90 97.84 ± 0.56 94.82 ± 4.65 95.30 ± 1.38 88.25 ± 2.51
Method 3 97.45 ± 1.07 98.67 ± 0.30 96.44 ± 2.35 96.41 ± 0.94 91.33 ± 1.75
Method 4 99.24 ± 0.25 99.36 ± 0.29 99.22 ± 0.40 98.32 ± 0.27 96.17 ± 0.52
Method 5 99.41 ± 0.20 99.52 ± 0.25 99.17 ± 0.37 98.84 ± 0.14 97.43 ± 0.27
Method 6 99.40 ± 0.17 99.54 ± 0.24 99.14 ± 0.35 98.80 ± 0.13 97.40 ± 0.26

Significant values are in bold.