Skip to main content
. 2020 Jul 27;10(46):27764–27774. doi: 10.1039/d0ra02826f

Comparison of performance of modified electrode with other 2,4-DNT sensors.

Material Technique LODg (μM) LDRf (μM) Ref.
G–LiClO4d DPV 14.98 30
G–Na2SO4e 31.4
Functionalized 3DOM carbon electrodesl SWVj 3 31
Pd–Pth DPVc 0.82 10–100 32
Disposable SPEi CV 0.7 0–200 33
Ag/Ca CVb 5 53
ZnO–Ag2O composite nanoflowers modified gold electrodek DPV 0.013 0.4–40 This work
a

Ag/C: zero valent silver modified carbon fiber material.

b

CV: cyclic voltammetry.

c

DPV: differential pulse voltammetry.

d

G–LiClO4: lithium perchlorate exfoliated graphene sheet.

e

G–Na2SO4: sodium sulphate exfoliated graphene sheet.

f

LDR: linear detection range.

g

LOD: limit of detection.

h

Pd–Pt: palladium–platinum nanostructures.

i

SPE: screen printed electrode

j

SWV: square wave voltammetry.

k

ZnO–Ag2O: zinc oxide–silver oxide

l

3DOM: three dimensionally ordered macroporous.