Correlation between sensitivity of Xpert Ultra and cerebrospinal fluid (CSF) testing protocol.

Sensitivity
CSF protocol
References
vs Culture vs CRS Volume (ml) Fresh/Frozen Centrifugation step
44.2% 1 Fresh No Wang et al., 2019
90% 95.4% 0.5 Frozen Yes (10 ml centrifugated and resuspended in 2 ml) Bahr et al., 2018
80% 63.6% 2 Fresh No Chin et al., 2019a
92.9% 0.5 Fresh Yes (unknown ml centrifugated and resuspended in 2 ml) Cresswell et al., 2020b
90.9% 59.5% 0.2 Fresh Yes (6 ml centrifugated and resuspended in 0.5 ml) Donovan et al., 2020
96.4% 72% 1 Fresh No Sharma et al., 2020
46.7% 1 Fresh No Shao et al., 2020
71.4% 45% 1 Fresh No Huang et al., 2021