Skip to main content
. 2022 May 19;2022:6185013. doi: 10.1155/2022/6185013

Table 1.

Different performance measure of the proposed capsule network model.

Method Class Precision Recall F1 score Accuracy (%)
Convolutional neural network Normal 0.65 0.83 0.88 77.9
Pneumonia 0.96 0.92 0.96 88.1
COVID 0.90 0.81 0.89 81.2

Proposed capsule network model Normal 0.89 0.87 0.90 86.6
Pneumonia 0.99 0.96 0.97 89
COVID 0.93 0.87 0.92 94