Skip to main content
. 2022 May 13;12:869982. doi: 10.3389/fonc.2022.869982

Table 4.

Differentiation performance of clinico-radiologic model, radiomics model, and combined model in the training and test cohorts.

Variables Training cohort Test cohort
AUC ACC (%) SEN (%) SPE (%) AUC ACC (%) SEN (%) SPE (%)
Clinico-radiologic model 0.860 (95% CI: 0.808-0.913) 83.6 71.2 91.4 0.843 (95% CI: 0.759-0.923) 84.5 70.4 93.2
Radiomics
model
0.965 (95% CI: 0.941-0.990) 89.5 83.3 93.3 0.961(95% CI: 0.917-1.000) 90.1 92.6 88.6
Combined
model
0.975 (95% CI: 0.956-0.995) 91.8 89.4 93.3 0.955(95% CI: 0.915-0.996) 85.9 81.5 88.6

AUC, area under the summary receiver operating characteristic curve; ACC, accuracy; SEN, sensitivity; SPE, specificity; CI, confidence interval.