Skip to main content
. Author manuscript; available in PMC: 2022 May 27.
Published in final edited form as: Phys Med Biol. 2021 May 31;66(11):10.1088/1361-6560/ac01b4. doi: 10.1088/1361-6560/ac01b4

Table 2.

Lung volume variation during respiration in 4D-CT.

Lung volume (cc) Phase 2 Phase 3 Phase 4 Phase 5 (EOE)
Training group Reference 4372.9 ± 1603.3 4240.1 ± 1600.0 4103.7 ± 1573.2 3991.9 ± 1535.6
Simulation 4399.8 ± 1592.0 4319.4 ± 1586.3 4239.0 ± 1574.0 4105.7 ± 1597.7
%Difference 1.0% 2.5% 3.8% 5.4%
Validation group Reference 3313.3 ± 675.11 3225.4 ± 650.59 3137.9 ± 621.17 3081.2 ± 592.35
Simulation 3338.9 ± 657.94 3311.8 ± 651.49 3275.2 ± 642.34 3244.7 ± 634.28
%Difference 1.2% 2.9% 4.6% 5.3%
Testing group Reference 3543.0 ± 1341.5 3416.2 ± 1339.0 3313.5 ± 1294.1 3248.6 ± 1269.8
Simulation 3550.2 ± 1317.8 3500.7 ± 1306.5 3456.6 ± 1291.6 3420.8 ± 1277.9
%Difference 0.7% 3.1% 4.8% 5.8%