Skip to main content
. 2022 May 20;11(10):2893. doi: 10.3390/jcm11102893

Table 1.

Studies of AI’s Application in Left Ventricular Systolic Function—LVEF.

Authors Year Task Model Dataset Results
Leclerc S. et al. [16] 2019 LV segmentation U-Net 500 subjects Accuracy in LV volumes (MAE = 9.5 mL, r = 0.95).
Smistad E. et al. [17] 2019 LV segmentation U-Net 606 subjects Accuracy for LV segmentation (DSC 0.776–0.786).
Leclerc S. et al. [18] 2020 LV segmentation LU-Net 500 subjects Accuracy in LV volumes (MAE = 7.6 mL, r = 0.96).
Wei H. et al. [28] 2020 LV segmentation CLAS 500 subjects Accuracy for LVEF assessment (r = 0.926, bias = 0.1%).
Reynaud H. et al. [29] 2021 LVEF assessment Transformer 10,030 subjects Accuracy for LVEF assessment (MAE = 5.95%, R2 = 0.52).
Ouyang et al. [19] 2020 LVEF assessment EchoNet-Dynamic 10,030 subjects Accuracy for LV segmentation (DSC = 0.92), LVEF assessment (MAE = 4.1%),
and HFpEF classification (AUC 0.97).
Asch F.M. et al. [20] 2019 LVEF assessment CNN >50,000 studies AutoEF values show agreement with GT: r = 0.95, bias = 1.0%,
with sensitivity 0.90 and specificity 0.92 for detection of EF less than 35%.
Zhang J. et al. [21] 2018 LVEF assessment GLS assessment Disease detection CNN 14,035 studies Agreement with GT: for LVEF, MAE = 9.7%;
for GLS, and MAE = 7.5% and 9.0% (within 2 cohorts).
Disease detection: HCM, Amyloid, and PAH (AUC 0.93, 0.87, and 0.85).
Tromp J. et al. [30] 2022 LVEF assessment CNN 43,587 studies Accuracy for LVEF assessment (MAE 6–10%).
Narang A. et al. [15] 2021 LVEF assessment Caption Guidance 240 subjects LV size, function, and pericardial effusion in 237 cases (98.8%)
and RV size in 222 cases (92.5%) are of diagnostic quality.
Asch F.M. et al. [32] 2021 LVEF assessment Caption Health 166 subjects (Protocol 1)
67 subjects (Protocol 2)
Protocol 1: agreement with GT: ICC 0.86–0.95, bias < 2%.
Protocol 2: agreement with GT: ICC = 0.84, bias 2.5 ± 6.4%.
Tokodi M. et al. [24] 2020 Disease detection (HFpEF) TDA 1334 subjects Region 4 relative to 1: HR = 2.75, 95%CI 1.27–45.95, p = 0.01.
Correlation of NYHA and ACC/AHA stages with regions: r = 0.56 and 0.67.

LVEF, left ventricular ejection fraction; LV, left ventricle; RV, right ventricle; MAE, mean absolute error; DSC, dice similarity coefficient; CLAS, Co-Learning of Segmentation and Tracking on Appearance and Shape Level; AUC, area under the receiver operating characteristic curve; CNN, convolutional neural network; GT, ground truth; GLS, global longitudinal strain; HCM, hypertrophic cardiomyopathy; PAH, pulmonary arterial hypertension; HFpEF, heart failure with preserved ejection fraction; HF, heart failure; ICC, intraclass correlation coefficient; TDA, topological data analysis; HR, hazard ratio; CI, confidence interval; NYHA, New York Heart Association; ACC, American College of Cardiology; AHA, American Heart Association.