. 2022 May 9;12(5):504. doi: 10.3390/membranes12050504

Table 1.

Comparison of analytical characteristics of wearable PANI, HIs and MOx pH sensors and sensors based on other materials.

Materials pH Range Sensitivity (mV/pH) RSD
(%)
Response Time On-Body Test Ref.
PANI 3–7 −57.5 ± 3.3 5.7 10–25 s 50 min [54]
PANI 4–8 −60.6 ± 1.8 3.0 [70]
PANI 2–12 −58.2 <10 s [71]
PANI 3–8 −63.3 ± 1.5 2.3 30 min [72]
PANI 4–8 −54.4 ± 1.9 3.5 <1 s 30 min [22]
PANI 4–8 −56.2 30 min [73]
PANI 4–8 −58.5 ± 0.7 1.2 <20 s [74]
PANI 4–10 −50 ~12 s [69]
PANI 3–8 −59.6 <30 s Chicken skin [75]
HIs (I) 3–11 −59.2 ± 3.0 <5 5 s [28]
HIs (I) 6.4–7.4 −51.8 [46]
HIs (I) 4–7.5 −56.0 ± 0.6 1.0 1 h [79]
HIs (I) 4–8 −58.2 ± 0.6 1.1 30 min [80]
IrOx 1.5–12 −51.1 to –51.7 2 s [52]
IrOx 4–9 −69.9 ± 2.2 3.1 0.5 s Rabbit and donated
human hearts
[37]
IrOx 2–10 −61 ± 1 1.6 [110]
IrOx −71.9 ± 0.8 1.1 >40 min [111]
IrOx 4–9 or
2–10
−65 to −75 <2 s [114]
ITO 2–12 −50.1 ± 4.1 8.2 [112]
ZnO 1–9 −59 [97]
IZO 4–10 −105 [51]
InGaZnO 3.3–11 −51.2 ~20 min [113]
WO3 5–9 −56.7 ± 1.3 2.3 23–28 s [93]
HxWO3 2–8 −53.6 ± 1.6 3.0 <10.5 s ~20 min [109]
SWCNTs 3–11 −59.7 ± 1.5 2.5 [47]
CCD 2.8–11.2 −240 100 s [115]
TA-RGO 1–10 −52.4 ± 0.7 1.3 20 min [116]