Skip to main content
. 2022 May 23;15:703–712. doi: 10.2147/JAA.S360260

Table 3.

FOT Parameters, FeNO, CAT, ACT and Blood Examination Parameters After Each Treatment

Run-In Control TIO Add-on P-value
FOT parameters
 R5 (cmH2O/L/s) 3.8 (1.1) 3.6 (1.2) 3.2 (1.1) < 0.05
 R20 (cmH2O/L/s) 2.9 (0.7) 2.7 (0.9) 2.5 (0.8) < 0.05
 X5 (cmH2O/L/s) −1.7 (1.0) −1.7 (1.2) −1.3 (0.9) < 0.05
 Fres (Hz) 16.9 (5.9) 16.8 (6.4) 15.1 (5.5) < 0.05
 ALX (cmH2O/L/s X Hz) 13.5 (11.0) 13.8 (12.6) 9.9 (9.3) < 0.05
 FeNO (ppb) 18.2 (8.4) 17.3 (7.6) 18.2 (8.3) 0.88
COPD Assessment Test score 15.4 (11.6) 17.6 (10.3) 15.8 (11.4) 0.11
Asthma Control Questionnaire score 6.0 (5.2) 6.4 (5.9) 7.5 (5.6) 0.18
Adherence Starts with Knowledge–12 score 25.1 (6.9) 22.2 (5.5) 22.1 (5.4) 0.08
Serum total Ig E (IU/mL) 899.9 (913.6) 876.9 (1057.8) 804.9 (961.3) 0.39
Peripheral eosinophil count (/mL) 297.5 (208.6) 304.0 (251.3) 281.7 (176.9) 0.78

Notes: Data are presented as mean (SD). P values were determined by one-way ANOVA.

Abbreviations: FOT, forced oscillation technique; R5 and R20, respiratory system resistance at 5 Hz and 20 Hz; X5, respiratory system reactance at 5 Hz; Fres, resonant frequency; ALX, area of low reactance; FeNO, the fraction of exhaled nitric oxide; COPD, chronic obstructive pulmonary disease; Ig, immunoglobulin.