Table 4.

Analyses of water sources for faecal indicator bacteria and hepatitis E virus (HEV) in the nursing home

Sample sources Sample size Collection date Test date Test items Test methods Test results Reference values*
Water well 1 5 Feb. 2015 5 Feb. 2015 Total bacteria count Plate count method 710 c.f.u./ml ⩽100 c.f.u./ml
The coliform group Lactose fermentation, separate cultivation and confirmatory test 1600 c.f.u./100 ml Negative
Thermotolerant coliform bacteria Membrane filter technique 1600 c.f.u./100 ml Negative
Water boiler 1 5 Feb. 2015 5 Feb. 2015 Total bacteria count Plate count method Negative ⩽100 c.f.u./ml
The coliform group Lactose fermentation, separate cultivation and confirmatory test Negative Negative
Thermotolerant coliform bacteria Membrane filter technique Negative Negative
Tap-water pipes 8 8 Feb. 2015 8 Feb. 2015 Total bacteria count Plate count method 0–3 c.f.u./ml ⩽100 c.f.u./ml
The coliform group Lactose fermentation, separate cultivation and confirmatory test Negative Negative
Thermotolerant coliform bacteria Membrane filter technique Negative Negative
HEV Real-time PCR Negative Negative
*

The reference values were derived from standards for drinking water quality issued by the Ministry of Health of China.

The water samples were collected from four different tap-water pipes. Of these, three were located in the rooms of different cases, while one was located in the refectory of the nursing home. Two samples were collected from each tap-water pipe.