Skip to main content
. 2022 Mar 22;8(2):545. doi: 10.18063/ijb.v8i2.545

Table 3.

Percentage increase in maximum wall shear stress (Pa) on decreasing diameter of nozzle outlet from 0.5 mm to 0.1 mm

Pressure (MPa) Tapered conical Conical Cylindrical
0.025 26.1 11.9 −79.4
0.050 31.7 21.1 −79.6
0.100 30.1 24.0 −78.2
0.150 30.5 25.7 −70.9
0.200 30.9 27.1 −62.8
0.250 30.9 27.1 −55.0