TABLE I.

PARAMETERS FOR THE TRAINING NETWORK

Category/Function Parameters Value/Range

Photoacoustic data Transducer width 15 mm
Transducer acoustic focus 40 mm
Transducer bandwidth 65%
Sampling rate 9 MHz
Transducer central frequency 2.25 MHz
Ultrasonic wavelength 0.68 mm
Transducer scanning step size 0.1 mm

Training image Image numbers 6400
Signal to Noise Ratio 6, 9, 12 dB, and noise free
Axial samples 256 pixels (50mm)
Elevation samples 256 pixels (50mm)

Training Batch size 8
Learning rate 0.001
Training iterations 41,490
Training time 1.7 hours