Table 4.

Diagnostic performance of the combined qualitative parameters of shear wave elastography (SWE) or/and AngioPLUS microvascular Doppler ultrasound technique (AP) with Breast Imaging Reporting and Data System (BI-RADS) in distinguishing malignant from benign lesions.

Sensitivity (%) Specificity (%) Positive predictive value (%) Negative predictive value (%) Accuracy (%) Area under the receiver operating characteristic curve (95%CI) p a
BI-RADS 95.5 (64/67) 46.9 45.7 95.7 62.4 71.2 (0.643–0.781)
BI-RADS + AP 86.6 (58/67) 79 65.9 92.6 81.4 82.8 (0.767–0.889) <0.001
BI-RADS + SWE 91.0 (61/67) 74.1 62.2 94.6 79.5 82.6 (0.767–0.885) <0.001
BI-RADS + AP + SWE 91.0 (61/67) 81.1 69.3 95.1 84.3 86.1 (0.806–0.916) <0.001

Data are expressed as percentage (numbers).

a

Comparison of the diagnostic performance between BI-RADS alone with the combination of the qualitative SWE and/or AP with BI-RADS.