Skip to main content
. 2022 Jun;43(6):872–880. doi: 10.3174/ajnr.A7529

Table 3:

Patient-wise diagnostic accuracy results by OR analysisa

SPACE vs MPRAGE SPACE vs VIBE P (SPACE vs MPRAGE) P (SPACE vs VIBE)
Chance of detecting more patients with TP
    ER 1 1.20 (0.6–2.4) 1.29 (0.6–2.6) .598 .478
    ER 2 1.00 (0.48–2.09) 1.00 (0.48–2.09) 1.000 1.000
    BR 1.08 (0.5–2.4) 1.18 (0.53–2.6) .686 .687
Chance of detecting more patients with FP
    ER 1 3.55 (1.4–9.1) 3.03 (1.25–7.3) .015b .027b
    ER 2 3.53 (1.5–8.4) 3.08 (1.3–7.1) .008b .015b
    BR 5.17 (2.1–12.7) 2.76 (1.3–5.7) <.001b .012b
a

OR and 95% CI are provided for SPACE versus MPRAGE and SPACE versus VIBE comparisons and for each reader.

b

Statistically significant results.