Skip to main content
. 2022 May 5;28(1):10.7196/AJTCCM.2022.v28i1.206. doi: 10.7196/AJTCCM.2022.v28i1.206

Table 5. Vital parameters on the device.

Parameters HFNC,
mean (SD)
NRBM,
mean (SD)
p-value OR (95% CI)
PaO2 on device 84.23 (9.202) 74.27 (4.160) <0.001 9.967 (6.276 - 13.657)
PaO2/FiO2 on device 264.60 (42.019) 216.62 (23.868) <0.001 47.979 (30.080 - 65.878)
SpO2 on device 95.17 (4.662) 93.53 (4.911) 0.7719 1.633 (–0.841 - 4.108)
RR 23.17 (2.086) 25.52 (0.871) 0.001 –1.351 (–2.189 - [–0.512])
HR 86.83 (3.815) 87.03 (1.732) 0.794 –0.20 (–1.0731 - 1.331)
MAP 74.00 (1.661) 73.20 (1.648) 0.661 0.80 (–0.055 - 1.655)
Patient satisfaction level 6.07 (0.691) 2.80 (0.761) 0.001 -

HFNC = high-flow nasal cannula

NRBM = non-rebreathing mask

OR = odds ratio

CI = confidence interval

PaO2 = partial pressure of oxygen

PaO2/FiO2 = ratio of partial pressure of oxygen and fraction of inspiratory oxygen

SpO2 = oxygen saturation

RR = respiration rate

HR = heart rate

MAP = mean arterial pressure