Skip to main content
. 2000 Jan;66(1):268–276. doi: 10.1128/aem.66.1.268-276.2000

TABLE 3.

Microbial populations isolated from the water column during biological treatmenta

Bacterial identification % Population in:
Raw water Ozone contactor Filter effluent Distribution system influent cPVC pipe effluent Iron pipe effluent
Gram negative
 Acidovorax spp. 2 4 7
 Acinetobacter spp. 29 6
 Agrobacterium spp. 18
 Alcaligenes spp. 12 2 1 12
 Alteromonas spp. 2
 Comamonas spp. 1 3
 Enterobacter spp. 2 5
 Flavobacterium spp. 2 5
 Hydrogenophaga spp. 8 3 1
 Klebsiella spp. 10 1 3
 Methylobacterium spp. 1 2
 Pseudomonas spp. 14 53 22 12
 Rhodobacter spp. 2 1
 Sphingomonas spp. 2 2 19
 Stenotrophomonas spp. 2 1 2 6
 Xanthobacter spp. 3
 Otherb 2 1 5
Gram positive
 Bacillus spp. 7 6 6
 Micrococcus spp. 6
 Nocardia spp. 1 3 7 53 46 82
 Rhodococcus spp. 16 4
 Staphylococcus spp. 1 1
 Other 1 1 1
Unidentified 3 9 16 33 0 6
a

One hundred isolates from each site were identified. 

b

Includes organisms isolated from only one site at a frequency of 1%.