Skip to main content
. 2021 Jan 15;3(1):20200061. doi: 10.1259/bjro.20200061

Table 2.

Trial imaging protocol

Sequence Purpose Flip angle,
TE, TR / ms
Parallel imaging factor Other Matrixa FOV / cm
TSE 2D
Turbo spin-echo
High resolution T 2W for tumour outlining 150°
96, 3890
None ETL 13 256 × 256 x 20 Limb:
25 × 25 x 10
Trunk:
38.6 × 38.6 x 10
EPI 2D
Echoplanar imaging
Diffusion-weighted imaging -
103, 1,2100
2 AP EPI factor 128,
B = 0, 50, 100, 150, 200, 500, 1000 s/mm2
128 × 128 x 20
SRTFE 3D
Saturation-recovery turbo field echo
T1 measurement 12°
1.52
64, 142, 292, 1050, 2550, 3950
2 AP TI = 37, 100, 250, 1000, 2500, 3900 ms
VIBE 3D
Volume-interpolated breath-hold imaging
Dynamic contrast-enhanced imaging 16°
0.81, 2.63
2 AP Temporal resolution
1.75 s, 150 dynamics

TE, echo time; TR, repetition time; TI, inversion time; FOV, field of view; 2D, two-dimensional; 3D, three-dimensional.

a