Table 1.

Acquisition parameters a,b

EPI sequence Resolution (mm3) FOV (mm3) Matrix Readout segments ES (ms) TR (ms) TEDW
/
TET2*W (ms)
# b = 0/
Diff. dir
Flip angle T2*W (°) in-plane GRAPPA Scan time (min)
rs-EPI DW single-contrast 1.0 × 1.0 × 3 256 × 256 × 150/256 × 256 × 120 256 × 256 × 20/256 × 256 × 10 9 0.34 4500/2250 81.5/– 1/3 2 3:09c/1:35c
rs-EPI T2*W single-contrast 1.0 × 1.0 × 3 256 × 256 × 150/256 × 256 × 120 256 × 256 × 20/256 × 256 × 10 9 0.34 4500/2250 –/24.8 20° 2 3:09c/1:35c
rs-EPI SMC 1.0 × 1.0 × 3 256 × 256 × 150/256 × 256 × 120 256 × 256 × 20/256 × 256 × 10 9 0.34 4500/2250 81.5/24.8 1/3 20° 2 3:09/1:35

aAll protocols, if applicable, acquired with b = 1000 s/mm2

bGaps between slices of 4.5 mm for 20 slices, and 9.0 mm for 10 slices were used

cScan time matched to that of rs-EPI SMC to maintain signal comparison between sequences

Scan time without additional ACS data and preparation for SMC (same TR) = 2:56 min/1:28 min

EPI echo planar imaging, ES echo spacing