Skip to main content
. 2022 Mar 18;29(7):1183–1190. doi: 10.1093/jamia/ocac033

Table 3.

Observed intervals between consecutive provider-entered vital sign values in the EHR

Vital sign parameter Time from admission Mean Median IQR
(h) (min) (min) (min)
Heart rate 0–72 h 57 min 55 min 48–72 min
 0–24 49 51 45–57
 24–48 61 57 49–77
 48–72 69 57 51–160
Systolic blood pressure 0–72 h 58 min 58 min 52–66 min
 0–24 57 57 49–65
 24–48 74 60 57–180
 48–72 67 60 55–75
Respiratory rate 0–72 h 58 min 60 min 30–60 min
 0–24 49 60 30–60
 24–48 61 60 60–60
 48–72 69 60 60–60
SpO2 0–72 h 63 min 60 min 52–81 min
 0–24 56 55 49–62
 24–48 65 60 53–90
 48–72 74 60 53–160