The comparison of advantages and disadvantages of thermal technologies presented in the review to measure the in-plane k of films [68, 73, 74]

Methods Advantages Disadvantages Sample geometry
Thermal bridge method Substrate effect eliminated; can obtain k directly The effect of thermal radiation losses and contact thermal resistance is ignored; extensive microfabrication works Nanoscale or microscale samples
Flash method Wide temperature range; fast and noncontact; low cost Need surface coating; need smooth film surfaces; need specific heat capacity and density  > 100 µm in thickness
3ω method Can obtain k directly; insensitive to the radiation and convective heat losses Microfabrication of the metal stripe; need good insulation layer Sub-micrometer thick samples
Steady-state infrared thermography Fast and noncontact; can obtain k directly Sample needs substantial optical absorptance and large emissivity; need extensive calibrations of the experimental set up Sub-micrometer thick samples