Skip to main content
. 2022 Jun 1;16:888814. doi: 10.3389/fnins.2022.888814

TABLE 3.

The agreement of lumen and vessel wall measurements (ICC values with 95% CI) between automatic and manual segmentation methods and between two manual reads.

Lumen area (mm2) Vessel wall area (mm2) Mean wall thickness (mm) Normalized wall index
ICC (GT1-X) (95% CI) 0.987 (0.985–0.989) 0.936 (0.928–0.943) 0.896 (0.883–0.907) 0.782 (0.756–0.805)
ICC (GT2-X) (95% CI) 0.988 (0.986–0.989) 0.951 (0.944–0.956) 0.907 (0.896–0.918) 0.797 (0.773–0.819)
ICC (GT1-GT2) (95% CI) 0.987 (0.985–0.988) 0.926 (0.916–0.934) 0.877 (0.862–0.891) 0.704 (0.671–0.734)

ICC, intraclass correlation coefficient; CI, confidence intervals; ICC (GT1-X), ICC analysis between first manual read and automatic read; ICC (GT2-X), ICC analysis between second manual read and automatic read; ICC (GT1–GT2), ICC analysis between two manual reads.