Table 7.
Summary of standard mp-MRI protocol used in image acquisition.
Pulse sequence | Dual echo T1W GRE | T2W TSE/FSE | Volume interpolated T1W 3D GREb | Diffusion weighted imagingc | |||
---|---|---|---|---|---|---|---|
2D GRE | 3D GREa | Single shot TSE/FSE | 3T | 1.5T | Single shot echo-planar imaging | ||
3T | 1.5T | ||||||
Physiology | Breath hold | Breath hold | Breath hold | Respiratory triggered | Breath hold | Breath Hold | |
Breath hold | |||||||
Duration | 21 s | 16 s | 20 s | 3 to 4 min | 20 s | 21 s | |
22 s | |||||||
Fat suppression | N/A | N/A | N/A | N/A | Chemical or spectral inversion recovery | Spectral inversion recovery | |
TE (IP/OP)d; TR (ms) | (4.6/2.3);160 to 180 | (2.5/1.3); 5.5 and (2.2/1.1); 4.0 | (4.6/2.3); 7.6 | 83 to 88; 1030 | 1.7 to 2.5; 4.0 to 4.5 | 1.4;4.3 | 60.8 to 74; 2075 to 4600 |
Flip angle (deg) | 70 | 10 to 12 | 10 | 180 | 10 to 12 | 10 to 12 | 90 |
Bandwidth (Hz) | 260 | 700 | 313 | 450 | 325 to 460 | 488 | 250 to 1446 |
Number of excitations | 1 | 0.7 to 1 | 1 | Half-Fourier | 1 | 1 | 2 |
Acceleration factor | 2 | 2 | 1 | 1 | 2 | 2 | 2 |
2 | |||||||
Matrix size | 256/320 × 134/152 | 294 × 224 | 192 × 320 | 170 × 256 | 256 × 320 | 132 × 320 | 130 to 38; 96 to 75 |
Field of view (cm) | 25 × 35 | 25 × 35 | 25 × 35 | 25 × 35 | 25 × 35 | 25 × 35 | 40 to 380; 28 to 75 |
Slice thickness (mm) | 5 to 6 | 3 to 4 | 3 to 5 | 5 | 2.5 to 4 | 2.5 to 4 | 6 |
Imaging was performed on clinical 1.5 Tesla or 3 Tesla systems.
VIBE (Siemens Healthcare), THRIVE (Philips Healthcare), LAVA (General Electric Healthcare).
Diffusion weighted imaging performed with two values (0 and ) with ADC map automatically derived.
IP = in phase, OP = opposed phase.