Skip to main content
. 2022 Jun 6;7(2):e27284. doi: 10.2196/27284

Table 3.

Frequency of generic and personalized flags based on continuous glucose monitor data in external data sets.

Data set Patients, n Patients with at least 4 weeks of data, n (%) Glucose flags, n (flags per patient per week) Time in range flagsa, n (flags per patient per week) Patients with mean glucose or time in range flag every week, n (%)



Genericb Personalizeda Genericc Personalizedd Generic Personalized
1 85 78 (92) 329 (0.1) 725 (0.22) 493 (0.15) 493 (0.12) 1 (1) 0 (0)
2 12 10 (83) 13 (0.22) 14 (0.24) 19 (0.33) 19 (0.16) 1 (10) 0 (0)
3 120 120 (100) 1417 (0.31) 1128 (0.25) 1535 (0.34) 1535 (0.15) 4 (3.3) 0 (0)
4 225 225 (100) 2595 (0.34) 2002 (0.26) 3204 (0.42) 3204 (0.16) 9 (4) 0 (0)
5 450 436 (97) 4137 (0.35) 3498 (0.29) 4895 (0.41) 4895 (0.21) 31 (7.1) 0 (0)
6 180 4 (2) 6 (0.38) 4 (0.25) 9 (0.56) 9 (0.19) 1 (25) 0 (0)
7 219 195 (89) 967 (0.58) 525 (0.31) 1360 (0.81) 1360 (0.18) 97 (49.7) 0 (0)
8 133 32 (24) 116 (0.84) 47 (0.34) 131 (0.95) 131 (0.22) 26 (81.3) 1 (3.1)

aPersonalized mean glucose (MG) flag triggered when MG>MG+10 mg/dL in baseline period.

bGeneric mean glucose flag triggered when mean bigeneric glucose >170 mg/dL.

cGeneric time in range flag triggered when the percentage of readings of 70-180 mg/dL was <60%.

dPersonalized time in range (TIR) flag triggered when TIR<TIR−10% points in baseline period.