Table 2.
Summary of Subscapularis Repair Construct Types in the Included Studies
Study | Tear Type | Repair | SR Stitch | SR Anchors | DR/TO Stitch | DR Anchors | Suture |
---|---|---|---|---|---|---|---|
Borbas 2021 | Lafosse II | SR |
|
DL 5.5 mm PEEK or 4.75 mm Swivelock (1 anchor) | N/A | N/A | NS or FiberTape |
Dyrna 2019 | Fox-Romeo II and III | SR vs HDR vs DR | Simple mattress | DL 4.5 mm Bio-Corkscrew (2 anchors) | Medial: knotless; Lateral: knotless | SL medial and DL lateral 4.75-mm absorbable SwiveLock (3 anchors) | SR: No. 2 FiberWire; DR: FiberTape |
Lorbach 2016 | Fox-Romeo II and III | SR | Double mattress | DL 5.5 mm Bio-Corkscrew (1 anchor) | N/A | N/A | No. 2 FiberWire |
Sgroi 2021 | Fox-Romeo III | SR |
|
5.5 mm Bio-Corkscrew or 5.5 mm Swivelock (1 anchor) | N/A | N/A | No. 2 FiberWire or FiberTape |
Wellmann 2009 | Full-Thickness Complete Tear | SR vs DR | Modified MA | DL 5.5 mm titanium Corkscrew (2 anchors) | Medial: horizontal mattress; Lateral: knotless | Medial: SL 5.0-mm titanium Corkscrew (2 anchors); Lateral: DL 4.5-mm Bio-PushLock (2 anchors) | No. 2 FiberWire |
Wheeler 2010 | Full-Thickness Complete Tear | SR vs TO | Horizontal mattress | DL 5.0 mm titanium Corkscrew (2 anchors) | Modified MA | 3 bone tunnels | No. 2 FiberWire |
SR, single row; DR, double row; TO, transosseous; HDR, hybrid double row; DL, double-loaded; SL, single-loaded; MA, Mason Allen; N/A, not applicable.