Skip to main content
. 2022 May 24;4(3):e1097–e1102. doi: 10.1016/j.asmr.2022.03.008

Table 1.

Testing Results for the 4- and 5-Strand Semitendinosus and Gracilis Allograft Constructs

Parameter 4-Strand (n = 10) 5-Strand (n = 10) P Value
Δ cyclic displacement at 100 N, mm 0.87 ± 0.24 1.11 ± 0.24 .038
Δ cyclic displacement at 250 N, mm 0.83 ± 0.24 1.07 ± 0.23 .037
Yield load, N 762 ± 151 707 ± 107 .35
Ultimate tensile strength, N 778 ± 155 735 ± 116 .49
Stiffness, N/mm 138 ± 5 138 ± 7 .96
Graft diameter, mm 8.5 ± 0.5 8.8 ± 0.6 .26

NOTE. Data are presented as mean ± standard deviation. Statistically significant differences are in bold.

More than 1,000 repetitions, the difference in graft length between the first 20-30 cycles and the last 10 cycles.